Description: Portable pH Meter Conductivity Meter Ion Meter Dissolved Oxygen Meter mV TDS Please note: Battery /Liquid/Powder cannot be included during the shipping Multiparameter water quality meter contains 8 measurement modes, the meter is suitable for measuring the pH,temp , conductivity, TDS, salinity, resistivity and DO. pH Mode: • Multiparameter water quality meter is equipped with a backlit LCD display. • 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers. • Automatic electrode diagnosis helps the user decide whether to replace the pH electrode. Ion Mode:(optional) • 2 to 5 points calibration, including the 8 concentration points can be selected. • Direct ion concentration readout simplifies the measurement process. • Selectable concentration units (ppm, mg/L, mol/L) and ionic valency. Conductivity/TDS/Salinity/Resistivity Modes: • 1 to 5 points calibration with automatic recognition for conductivity standards. • Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes. Dissolved Oxygen Mode: • 1 or 2 points calibration using the air-saturated water or zero oxygen solution. • Salinity and barometric pressure compensations eliminate the measurement error. Other Features: • Automatic temperature compensation ensures accurate readings over the entire range. • Auto-Read function senses and locks the measurement endpoint. • Calibration due alarm prompts user to calibrate the meter regularly. • Calibration report provides the details of electrode performance. • Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, auto-power off, etc. • Reset function automatically resumes all settings back to the factory defaults. • Expanded memory stores or recalls up to 500 data sets. • USB communication interface is easy to transfer data to PC. • Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the meter smoothly. Specification: Model / pH Range -2.000~20.000pH Accuracy ±0.002pH Resolution 0.001, 0.01, 0.1pH, selectable Calibration Points 1 to 5 points pH Buffer Options USA, NIST, DIN or custom mV Range ±1999.9mV Accuracy ±0.2mV Resolution 0.1, 1mV, selectable Calibration Points 1 point Measurement Modes Relative or absolute mV Ion(optional) Range 0.001~19999 (Deponding on the range of ISE) Accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Resolution 0.001, 0.01, 0.1, 1, automatic Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) Measurement Units ppm, mg/L, mol/L or mmol/L Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm Accuracy ±0.5% F.S Resolution 0.001, 0.01, 0.1, 1, automatic Calibration Points 1 to 5 points Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm Temperature Coefficient Linear (0.0~10.0%/°C) or pure water compensation Cell Constant K=0.1, 1, 10 or custom Reference Temperature 20°C or 25°C TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) Accuracy ±1% F.S Resolution 0.01, 0.1, 1, automatic TDS Factor 0.1~1.0 (Default 0.5) Salinity Range 0.00~80.00ppt, 0.00~42.00psu Accuracy ±1% F.S Resolution 0.01 Measurement Modes Practical salinity (psu) or natural seawater (ppt) Resistivity Range 0.00~20.00MΩ Accuracy ±1% F.S Resolution 0.01 Dissolved Oxygen DO Range 0.00~20.00mg/L Accuracy ±0.2mg/L Resolution 0.01, 0.1mg/L, selectable % Saturation of Oxygen 0.0~200.0% Accuracy ±2.0% Resolution 0.1, 1%, selectable Calibration Points 1 or 2 points Pressure Correction 60.0~112.5kPa, 450~850mmHg, manual Salinity Correction 0~50g/L, manual Temperature Range 0~105°C, 32~221°F Accuracy ±0.5°C, ±0.9°F Resolution 0.1°C, 0.1°F Offset Calibration 1 point Calibration Range Measured value ±10°C General Temperature Compensation 0~100°C, 32~212°F, manual or automatic Stability Criteria Low or high Calibration Due Alarm 1 to 31 days or off Memory Stores up to 500 data sets Output USB communication interface Connector BNC, 6-pin DIN Display 3.5" custom LCD Power 3×1.5V AA batteries or DC5V power adapter Battery Life Approximately 150 hours (Turn off the backlit) Auto-Power Off 10, 20 or 30 minutes after last key pressed Dimensions 170(L)×85(W)×30(H)mm Weight 300g Packing : E201-BNC pH electrode CON-1 conductivity electrode DO100 dissolved oxygen electrode TP-10K temperature probe DO membrane cap Carrying case
Price: 885 USD
Location: 合肥
End Time: 2024-10-29T08:23:07.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
pH Accuracy: ±0.002pH
Conductivity Calibration Points: 1 to 5 points
TDS Range: 0.00~80.00ppt, 0.00~42.00psu
mV Range: -1999.9~1999.9mV
mV Resolution: 0.1/1mV, selectable
Warranty: 1 year
mV Calibration Points: 1 point
TDS Accuracy: ±1% F.S
TDS Factor: 0.1~1.0 (Default 0.5)
pH Calibration Points: 1 to 5 points
Conductivity Range: 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0m
pH Range: -2.000~20.000pH
pH Resolution: 0.1/0.01/0.001pH, selectable
Ion Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
MPN: Bante900P
Brand: VTSYIQI
Conductivity Resolutions: 0.01/0.1/1
Type: Water Quality Analyzer
mV Accuracy: ±0.2mV
Features: Digital, Temperature
Conductivity Accuracy: ±0.5% F.S
Country/Region of Manufacture: China