Description: MJ Research PTC-100 Programmable Thermal Controller. Unit is in fair condition with some scuffs, scratches, and general wear from use (see pictures, comes as shown). Device powers on and will run preprogramed test, was tested to 100C and was able to hold bottom plate at temperature. Top plate did not heat, cable has a bad spot (pictured). Unit beeps every second while running test, reason per manual is the top hot plate is not detected. Info on Thermal Controller:MJ ResearchSN: 16168model: PTC-100Rating: 100-240 VAC | 50-60 Hz | 350WattsFuses: (2) 4.0A 250V Manufacturer's Description:The MJ Research PTC-100 is a robust thermocycler that provides solutions for various temperature configuration needs. This instrument comes in versions that use of 96-well or 60-well microplates, as well as a heated lid for oil-free operation. The Hot Bonnet heated lid fitted in each unit has a thumbwheel that allows for the convenient adjustment of height and pressure. The modification feature ensures the tight sealing of reaction vessels ¬and microplates ¬ during oil-free thermal cycling.The Precise Peltier-effect heat pumps of PTC-100 thermocyclers were crafted to withstand repeated cycling. Any temperature sequence can be cycled up to 10,000 times. The NIST-traceable calibration feature of this instrument allows for the indefinite storing of material at any temperature. As a result, incubation rates are highly accurate. This calibration feature is also responsible for the refrigeration of results after unsupervised runs.Data storage is secured and hassle-free with MJ Research PTC-100 thermocyclers. Memory stores approximately 320 programs, and the cycler comes with 14 pre-programmed protocols. Any sequence of temperatures can be cycled up to 10,000 times. Ramping rates less than maximum can also be specified. Data which were not properly stored due to power interruptions are safe for up to twelve hours with the PTC-100’s power-failure protection feature.ALL QUESTIONS AND OFFERS WELCOME
Price: 189 USD
Location: Fayette, Alabama
End Time: 2024-08-21T15:22:22.000Z
Shipping Cost: 35 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Thermal Cycler Type: Standard Thermal Cycler/PCR System
MPN: PTC100
Number of Wells: 96
Intended Use/Discipline: Medical Laboratory
Brand: MJ Research
Model: MJ Research PTC-100