NISMO

617A Solar Hot Water Return Water Temperature Difference Comparison Controller

Description: Description Intelligent Temperature Difference Backwater Circulation Thermostat Comparison Controller with 10M Meter for Engineering Solar Energy Description: - HS-617A solar hot water return water temperature difference comparison controller circulating pump digital display adjustable instrument switch User manual First, the basic configuration: Product model: HS-617A 1. Control object: Control 1 channel electrical appliance is output by A channel, voltage range: 85-250VAC, power ≤ 2000W. 2. Temperature detection: high temperature, low temperature, two-way temperature detection corresponding to Atemp high temperature, Btemp low temperature display, detection range: 1~110° 3. Temperature difference adjustment range: the upper limit temperature difference is 3~40°, and the lower limit temperature difference is 1~35 (the factory default upper limit temperature difference is 5°, and the lower limit temperature difference is 2°). Second, various displays and tips: 1. Power-on display and prompt: After power-on, the digital tube will display in full screen and all the indicators will light for 2 seconds, while the beep will sound 2 times and then the relay will pick up 2 times. 2. Standby display: After the initial display of power-on, the standby display is displayed. The two display windows of Atemp and Btemp display the detected temperature. 3. Temperature control operation display: Turn on the temperature control ‘Run' indicator light, turn off the temperature control ‘Run’ indicator is off; When the output is turned on, the A light is on, and the A light is off when the output is off. Third, the basic functions and parameters: 1. Prerequisites for temperature control: After A ≥ 30°, enter the temperature difference comparison operation (factory default 30°, the value can be improved by the actual needs, the adjustment range is 1-110°) 2. Heating mode: When A is greater than B temperature ≥ temperature difference upper limit, the output is turned on. When the temperature difference between two temperature zones is ≤ temperature difference lower limit, the output is turned off. 3. Detecting temperature calibration: If the temperature measurement is not accurate, the system can be calibrated according to the actual temperature (see Advanced Settings 2 for details) 4. Antifreeze protection: When standby, when the detection temperature of A channel is ≤3°C, the circuit will open the output, and ≥5°C will turn off the output. 5. Temperature measurement circuit fault alarm: When a temperature sensing circuit is short-circuited or open circuit, the buzzer sounds, the corresponding display window displays E1, and the circuit resumes normal operation. 6. Permanent memory: All the parameters set last need to be saved, and the power will be cut off during operation. When the power is restored, it will run according to the state before power off. Fourth, common operations: 1. Switching machine operation: Press ‘ key’ to turn on temperature control during standby, press ‘ key’ to turn off temperature control during operation. 2. Temperature difference setting: short press 'key' in standby, A temperature flashes to display H05, press ' or '' to adjust the upper temperature limit, then press ' key' B to flash to display L02, press ' or ' to adjust the temperature difference Lower limit value, press ' key' to save the settings and return to standby. Five, advanced settings: (The long press action set below must be operated in the thermostat host) 1. A temperature zone premise value setting: (Adjustment range 1~110°) Press ‘5 seconds during standby time, Atemp flashes 30, press ‘ or ’ to adjust, press ‘ key’ to save the setting and return to standby. 2. Detect temperature calibration: Press ‘ ’ at the standby time to display the detected temperature, press ‘ or ’ to adjust, then press ‘ button ’ Btemp flashes, press ‘ or ’ to adjust, press ‘ button’ to save the setting and return to standby. Example 1: Split solar water heating cycle Operation mode: When the temperature difference between the temperature ranges of A and B probes ≥ the upper limit of the temperature difference, the output is turned on, and when the temperature difference between the two temperature zones ≤ the lower limit of the temperature difference, the output is turned off. Example 2: Temperature difference control backwater Payment Terms 1.We accept PayPal only. 2.All major credit cards are accepted through secure payment processor PayPal. 3.Payment must be received within 7 business days of auction closing. 4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay. Shipping Terms - For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding. Return Terms 1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund. 2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA. 3. We reserve the right to refuse any returns for objective reasons. Custom Duties & Taxes 1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility. 2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping. Feedback 1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers. 2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap. Am 18.04.22 hat der Verkäufer die folgenden Angaben hinzugefügt:Am 27.12.2022 hat der Verkäufer die folgenden Angaben hinzugefügt:

Price: 22.98 EUR

Location: Shenzhen

End Time: 2024-12-05T03:32:13.000Z

Shipping Cost: 5.29 EUR

Product Images

617A Solar Hot Water Return Water Temperature Difference Comparison Controller617A Solar Hot Water Return Water Temperature Difference Comparison Controller617A Solar Hot Water Return Water Temperature Difference Comparison Controller

Item Specifics

Rücksendekosten trägt: Verkäufer trägt die Kosten der Rücksendung der Waren

Rücknahme akzeptiert: Verbraucher haben das Recht, den Artikel unter den angegebenen Bedingungen zurückzugeben.

Nach Erhalt des Artikels sollte Ihr Käufer innerhalb der folgenden Frist den Kauf widerrufen oder den Rückgabeprozess einleiten: 30 Tage

Rücknahme - Weitere Angaben: Widerrufsrecht Sie haben das Recht, binnen eines Monats ohne Angabe von Gründen diesen Vertrag zu widerrufen. Die Widerrufsfrist beträgt einen Monat ab dem Tag, an dem Sie oder ein von Ihnen benannter Dritter, der nicht der Beförderer ist, die Waren in Besitz genommen haben bzw. hat. Um Ihr Widerrufsrecht auszuüben, müssen Sie uns [shen zhen shi tian zhong tian mao yi you xian gong si], [Room 303 Building 2 Youpin Cultural Creative Park Zhangkeng Minzhi Street shen zhen shi, 518000 China], [telefonnummer: 0086 19925132172], [Faxnummer: 0086 0755-23915394] [e - mail:outstandingdeal_de@hotmail.com] mittels einer eindeutigen Erklärung (z. B. ein mit der Post versandter Brief, Telefax oder E-Mail) über Ihren Entschluss, diesen Vertrag zu widerrufen, informieren. Sie können dafür das beigefügte Muster-Widerrufsformular verwenden, das jedoch nicht vorgeschrieben ist. Zur Wahrung der Widerrufsfrist reicht es aus, dass Sie die Mitteilung über die Ausübung des Widerrufsrechts vor Ablauf der Widerrufsfrist absenden. Folgen des Widerrufs Wenn Sie diesen Vertrag widerrufen, haben wir Ihnen alle Zahlungen, die wir von Ihnen erhalten haben, einschließlich der Lieferkosten (mit Ausnahme der zusätzlichen Kosten, die sich daraus ergeben, dass Sie eine andere Art der Lieferung als die von uns angebotene, günstigste Standardlieferung gewählt haben), unverzüglich und spätestens binnen vierzehn Tagen ab dem Tag zurückzuzahlen, an dem die Mitteilung über Ihren Widerruf dieses Vertrags bei uns eingegangen ist. Für diese Rückzahlung verwenden wir dasselbe Zahlungsmittel, das Sie bei der ursprünglichen Transaktion eingesetzt haben, es sei denn, mit Ihnen wurde ausdrücklich etwas anderes vereinbart; in keinem Fall werden Ihnen wegen dieser Rückzahlung Entgelte berechnet. Wir können die Rückzahlung verweigern, bis wir die Waren wieder zurückerhalten haben oder bis Sie den Nachweis erbracht haben, dass Sie die Waren zurückgesandt haben, je nachdem, welches der frühere Zeitpunkt ist. Sie haben die Waren unverzüglich und in jedem Fall spätestens binnen vierzehn Tagen ab dem Tag, an dem Sie uns über den Widerruf dieses Vertrags unterrichten, an uns oder an [shiyan song,5h gebäude b, yueshang center, longhua district, shenzhen,guangdong, china] zurückzusenden oder zu übergeben. Die Frist ist gewahrt, wenn Sie die Waren vor Ablauf der Frist von vierzehn Tagen absenden. Wir tragen die Kosten der Rücksendung der Waren. Sie müssen für einen etwaigen Wertverlust der Waren nur aufkommen, wenn dieser Wertverlust auf einen zur Prüfung der Beschaffenheit, Eigenschaften und Funktionsweise der Waren nicht notwendigen Umgang mit ihnen zurückzuführen ist. Muster-Widerrufsformular (Wenn Sie den Vertrag widerrufen wollen, dann füllen Sie bitte dieses Formular aus und senden Sie es zurück.) [shen zhen shi tian zhong tian mao yi you xian gong si], [Room 303 Building 2 Youpin Cultural Creative Park Zhangkeng Minzhi Street shen zhen shi, 518000 China], [telefonnummer: 0086 19925132172], [Faxnummer: 0086 0755-23915394] [e - mail:outstandingdeal_de@hotmail.com] – Hiermit widerrufe(n) ich/wir (*) den von mir/uns (*) abgeschlossenen Vertrag über den Kauf der folgenden Waren (*)/die Erbringung der folgenden Dienstleistung (*) – Bestellt am (*)/erhalten am (*) – Name des/der Verbraucher(s) – Anschrift des/der Verbraucher(s) – Unterschrift des/der Verbraucher(s) (nur bei Mitteilung auf Papier) – Datum

Herstellernummer: nicht zutreffend

Marke: Markenlos

Produktart: Temperature Difference Backwater Circulation Therm

Modell: HS-617A

Modifizierter Artikel: Nein

Herstellungsland und -region: China

Angebotspaket: Nein

Recommended

617a Engineering Solar Differential Temperature Cycle Thermostat Controller
617a Engineering Solar Differential Temperature Cycle Thermostat Controller

$42.54

View Details
617a Engineering Solar Differential Temperature Cycle Thermostat Controller
617a Engineering Solar Differential Temperature Cycle Thermostat Controller

$35.29

View Details
617A Solar Hot Water Return Water Temperature Difference Comparison Controller
617A Solar Hot Water Return Water Temperature Difference Comparison Controller

$23.92

View Details
Comparison Thermostat Hot Water Pump Automatic Cycle Thermostat 617A
Comparison Thermostat Hot Water Pump Automatic Cycle Thermostat 617A

$42.09

View Details
HS-617A Intelligent Temperature Difference Thermostat Comparison Controller os67
HS-617A Intelligent Temperature Difference Thermostat Comparison Controller os67

$25.18

View Details