Description: 3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu Scanner 3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu ScannerSINOCMP 3165033 Full 8 cable INLINE 6 Data Link Adapter Insite Heavy Duty Diagnostic Tool Scanner INLINE 6 Data Link Adapter For Cummins Get INLINE 6 for 5 Reasons: The INLINE 6 can communicate with your PC through a 9-pin serial connector. The INLINE 6 also can communicate with your PC over a Universal Serial Bus (USB) through a 4-pin standard connector. The INLINE 6 adapter connects to vehicle power, the SAE J1708/J1587 data link, and two CAN/J1939 data links via a 25-pin serial connector. With full compliance to the Technology and Maintenance Council's RP1210 standard, the INLINE 6 will work with the latest INSITE, PowerSpec and Calterm III software applications. It will also work with any other software applications that are fully compliant with the RP1210 standard (note that while some non- applications fully support RP1210, others do not, so you should test each application in question with the INLINE 6 adapter to make that determination). The eye-catching INLINE 6 breaks new ground by utilizing the latest electronic technology to deliver high performance and high quality at an attractive price. Each INLINE kit contains a data link adapter, basic cables, and the INLINE PC software driver. Load the software driver, connect all the hardware, and you are ready to start a new era in data link adapters.INLINE 6 Features: Supports SAE J1708/J1587 and J1939/CAN data links Both CAN ports auto detect between 250 & 500 kbps Supports USB full speed port at up to 2M baud rate Custom USB cable includes thumbscrews for secure mounting to INLINE 6 Supports RS-232 PC serial port at up to 115.2k baud rate Is fully compliant with TMC's RP1210 standard Small enough to fit in pocket Attractive black powder coated aluminum housing provides ruggedness Derives 8 V to 50 V DC power from vehicle Controlled by advanced 140 MHz 32-bit Freescale processor for maximum speed and performance Includes 6 LEDs to indicate status of power, USB, RS-232, J1708/J1587, and two CAN communication ports Both CAN ports support SAE J1939, SAE J2534, and ISO 15765 protocols INLINE 6 is certified to meet European CE requirements Rated for -40° to +85° C operating temperature INLINE 6 meets rigorous in-cab environmental test requirements Inline 6 data link adapter Support Language: Package Including: 1 x INLINE 6 data link adapter (P/N 2892093) 1 x USB 14-foot cable (P/N 2892176) 1 x DB25F/9-pin data link cable (P/N 4919780) 1 x DB25F/3-pin/3-pin/2-pin cable (P/N 4919797) 1 x J1939 Gender Changer adapter (P/N 3163597) 1 x J1939 Backbone adapter (P/N 3163096) 1 x ObdII cable (P/N 4919781) 1 x INLINE 6 software CD (P/N 2892095) Include Insite 7.6.2 + keygen INLINE 6 Quick Start Guide Introduction The INLINE 6 is a highly reliable datalink adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software. Minimum System Requirements Microprocessor – Intel Pentium 500 MHz Memory – 2 GB CD Drive Operating System – Windows 7, Vista, & XP SP3 To Install the INLINE 6 Software Driver • Insert the INLINE 6 driver CD into your computer’s CD-ROM drive. • Run INLINE6_Driver_Setup.exe • If a Windows Explorer folder opens, select INLINE6_Driver_Setup.exe Note that on some systems the autorun settings may be set to have the installation to just begin executing upon CD insertion. IF YOU SEE: WINDOWS XP - A message appear stating “The software you are installing has not passed Windows Logo…” Click “Continue Anyway”. Click “Finish” when installation is complete. To Install the INLINE 6 USB Hardware: To install the INLINE 6 USB hardware, power up the INLINE 6 by plugging in the USB cable provided with the kit to the INLINE 6 and the PC. WINDOWS XP - The Found New Hardware wizard should be displayed.On the first screen, select “Install the software automatically (Recommended)”. Click “Next” to continue. A message may appear “This software has not passed Windows Logo Testing……” Select “Continue Anyway”. Click “Finish” when installation is complete. WINDOWS VISTA/WINDOWS 7 - No action is required. The system tray should display a balloon stating “Installing Cummins Inline 6”. NOTE: If there is a previously installed INLINE 6 driver, you may need to remove the older driver before proceeding. After you have connected your INLINE 6 to your computer and the computer recognizes it as a valid device – you may need to update the firmware in the adapter. Please see the section below on using the INLINE 6 Reflash Tool Using Your INLINE 6 To use the INLINE 6, you must select it from within the application you areusing. Each application has a unique method for selecting datalink adapters.Please refer to the application’s documentation for instructions on selectingRP1210 compliant adapters. To Uninstall the INLINE 6 Software Driver WINDOWS XP- To remove the Cummins INLINE 6 driver, click the “Start”button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Add or Remove Programs” Click on the entry “Cummins Inline6”. Click the “Remove” button. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. WINDOWS VISTA/WINDOWS 7 – To remove the Cummins INLINE 6 driver, click the “Start” button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Programs/Features” Click the entry “Cummins Inline6’, Click “Uninstall” at the top of the Programs/Features window. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. Shipping PolicyPayment MethodReturns PolicyAbout USShipping PolicyPayment Method Accept PayPal Only. Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are the buyer’s responsibility. Returns Policy We offer return or exchange service in the warranty. Refund will be given after receiving the return parts(Buyer pays return shipping). We maintain high standards of excellence POSITIVE FEEDBACK and strive for 100% customer satisfaction! About US Maintenance service: repairing for monitor, ECU computer and hydraulic pump; monitor hours resetting, etc.HomePaymentShippingAbout usContact usStore CategoriesStore CategoriesCMP PARTSKOMATSU PARTSMonitorsControllersOthersHITACHI PARTSMonitorsControllersOthersVOLVO PARTSMonitorsControllersOthersKOBELCO PARTSMonitorsControllersOthersHYUNDAI PARTSDAEWOO&DOOSAN PARTSSUMITOMO PARTSCUMMINS PARTSENGINE PARTSEngine for CaterpillarEngine for IsuzuEngine for MitsubishiEngine for YanmarEngine for KomatsuEngine for KubotaEngine for CumminsEngine for DoosanEngine for HinoEngine for ToyotaEngine for NissanEngine for HyundaiFuel InjectorsFuel PumpsOthersEXCAVATOR DIAGNOSTIC TOOLCar & Truck PartsOther PartsOther Product Views 3165033 Inline 6 Data Link Adapter Diagnostic Tool For Cummins Komatsu ScannerSINOCMP 3165033 Full 8 cable INLINE 6 Data Link Adapter Insite Heavy Duty Diagnostic Tool Scanner INLINE 6 Data Link Adapter For Cummins Get INLINE 6 for 5 Reasons: The INLINE 6 can communicate with your PC through a 9-pin serial connector. The INLINE 6 also can communicate with your PC over a Universal Serial Bus (USB) through a 4-pin standard connector. The INLINE 6 adapter connects to vehicle power, the SAE J1708/J1587 data link, and two CAN/J1939 data links via a 25-pin serial connector. With full compliance to the Technology and Maintenance Council's RP1210 standard, the INLINE 6 will work with the latest INSITE, PowerSpec and Calterm III software applications. It will also work with any other software applications that are fully compliant with the RP1210 standard (note that while some non- applications fully support RP1210, others do not, so you should test each application in question with the INLINE 6 adapter to make that determination). The eye-catching INLINE 6 breaks new ground by utilizing the latest electronic technology to deliver high performance and high quality at an attractive price. Each INLINE kit contains a data link adapter, basic cables, and the INLINE PC software driver. Load the software driver, connect all the hardware, and you are ready to start a new era in data link adapters.INLINE 6 Features: Supports SAE J1708/J1587 and J1939/CAN data links Both CAN ports auto detect between 250 & 500 kbps Supports USB full speed port at up to 2M baud rate Custom USB cable includes thumbscrews for secure mounting to INLINE 6 Supports RS-232 PC serial port at up to 115.2k baud rate Is fully compliant with TMC's RP1210 standard Small enough to fit in pocket Attractive black powder coated aluminum housing provides ruggedness Derives 8 V to 50 V DC power from vehicle Controlled by advanced 140 MHz 32-bit Freescale processor for maximum speed and performance Includes 6 LEDs to indicate status of power, USB, RS-232, J1708/J1587, and two CAN communication ports Both CAN ports support SAE J1939, SAE J2534, and ISO 15765 protocols INLINE 6 is certified to meet European CE requirements Rated for -40° to +85° C operating temperature INLINE 6 meets rigorous in-cab environmental test requirements Inline 6 data link adapter Support Language: Package Including: 1 x INLINE 6 data link adapter (P/N 2892093) 1 x USB 14-foot cable (P/N 2892176) 1 x DB25F/9-pin data link cable (P/N 4919780) 1 x DB25F/3-pin/3-pin/2-pin cable (P/N 4919797) 1 x J1939 Gender Changer adapter (P/N 3163597) 1 x J1939 Backbone adapter (P/N 3163096) 1 x ObdII cable (P/N 4919781) 1 x INLINE 6 software CD (P/N 2892095) Include Insite 7.6.2 + keygen INLINE 6 Quick Start Guide Introduction The INLINE 6 is a highly reliable datalink adapter that can be used on a wide range of applications to communicate with vehicle systems via SAE J1708/J1587 and SAE J1939 protocols. Please note that the INLINE 6 is designed to be used with RP1210 compliant software. Minimum System Requirements Microprocessor – Intel Pentium 500 MHz Memory – 2 GB CD Drive Operating System – Windows 7, Vista, & XP SP3 To Install the INLINE 6 Software Driver • Insert the INLINE 6 driver CD into your computer’s CD-ROM drive. • Run INLINE6_Driver_Setup.exe • If a Windows Explorer folder opens, select INLINE6_Driver_Setup.exe Note that on some systems the autorun settings may be set to have the installation to just begin executing upon CD insertion. IF YOU SEE: WINDOWS XP - A message appear stating “The software you are installing has not passed Windows Logo…” Click “Continue Anyway”. Click “Finish” when installation is complete. To Install the INLINE 6 USB Hardware: To install the INLINE 6 USB hardware, power up the INLINE 6 by plugging in the USB cable provided with the kit to the INLINE 6 and the PC. WINDOWS XP - The Found New Hardware wizard should be displayed.On the first screen, select “Install the software automatically (Recommended)”. Click “Next” to continue. A message may appear “This software has not passed Windows Logo Testing……” Select “Continue Anyway”. Click “Finish” when installation is complete. WINDOWS VISTA/WINDOWS 7 - No action is required. The system tray should display a balloon stating “Installing Cummins Inline 6”. NOTE: If there is a previously installed INLINE 6 driver, you may need to remove the older driver before proceeding. After you have connected your INLINE 6 to your computer and the computer recognizes it as a valid device – you may need to update the firmware in the adapter. Please see the section below on using the INLINE 6 Reflash Tool Using Your INLINE 6 To use the INLINE 6, you must select it from within the application you areusing. Each application has a unique method for selecting datalink adapters.Please refer to the application’s documentation for instructions on selectingRP1210 compliant adapters. To Uninstall the INLINE 6 Software Driver WINDOWS XP- To remove the Cummins INLINE 6 driver, click the “Start”button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Add or Remove Programs” Click on the entry “Cummins Inline6”. Click the “Remove” button. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. WINDOWS VISTA/WINDOWS 7 – To remove the Cummins INLINE 6 driver, click the “Start” button on the Windows task bar, and then navigate to “Control Panel”. Navigate to “Programs/Features” Click the entry “Cummins Inline6’, Click “Uninstall” at the top of the Programs/Features window. This will start the uninstall process. Wait until the uninstall process has completed before proceeding. Please Note: Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are the buyer’s responsibility.Shipping PolicyPayment MethodReturns PolicyAbout USShipping PolicyPayment Method We accept PayPal, VISA, MasterCard, Debit Card through PayPal. Import duties, taxes and customs clearance fees are not included in the item price or shipping charges. These charges are the buyer’s responsibility. Returns Policy We offer return or exchange service in the warranty. Refund will be given after receiving the return parts(Buyer pays return shipping). We maintain high standards of excellence POSITIVE FEEDBACK and strive for 100% customer satisfaction! About US Maintenance service: repairing for monitor, ECU computer and hydraulic pump; monitor hours resetting, etc.HomePaymentShippingAbout usContact us
Price: 199 USD
Location: Hongkong
End Time: 2024-02-29T08:32:15.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Brand: SINOCMP
Compatible Equipment Make: Cummins
Compatible Equipment Type: Car, Crawler Dozer, Excavator, Truck
Country/Region of Manufacture: China
EAN: Does not apply
Features: Multi-Language Interface
Manufacturer Part Number: 3165033
Model: Inline 6
MPN: 3165033
Origin: CN(Origin)
Part Type: Diagnostic Adapter
UPC: Does not apply
Warranty: 1 Year